Heating Capacity (+7°C / +35°C floor heating)
13.50 kW
Input Power (+7°C / +35°C floor heating)
3.20 kW
COP (+7°C / +35°C floor heating)
4.22
Heating Capacity (+2°C / +35°C floor heating)
13.00 kW
Input Power (+2°C / +35°C floor heating)
4.15 kW
COP (+2°C / +35°C floor heating)
3.13
Heating Capacity (-7°C / +35°C floor heating)
12.20 kW
Input Power (-7°C / +35°C floor heating)
5.13 kW
COP (-7°C / +35°C floor heating)
2.38
Heating Capacity (+7°C / +45°C radiators)
12.60 kW
Input Power (+7°C / +45°C radiators)
3.81 kW
COP (+7°C / +45°C radiators)
3.30
Heating Capacity (-7°C / +45°C radiators)
12.50 kW
Input Power (-7°C / +45°C radiators)
6.00 kW
COP (-7°C / +45°C radiators)
2.08
Backup Heater Capacity
9.0 kW × pcs. (3.0 × 3 pcs.)
Model Name (Hydraulic Unit)
WGYK160DG9
Power Source (Hydraulic Unit)
3 N 400 V 50 Hz
Water Circulation (Rated)
39.0 L/min
Water Circulation (Min / Max)
24.4 / 48.7 L/min
Dimensions (Hydraulic Unit) H×W×D
1840 × 648 × 698 mm
Weight (Net) (Hydraulic Unit)
152 kg
Hot Water Heater Capacity
1.5 kW
Buffer Tank Capacity
16 L
Expansion Vessel Capacity
12 L
Leaving Water Temperature Range
8 ~ 60°C
Water Pipe Connection Diameter (Flow / Return)
Φ25.4 / Φ25.4 mm
Hot Water Pipe Diameter (Inlet/Outlet)
Φ19.05 mm
Space Heating Temperature Application
55°C
Energy Efficiency Class (Space Heating)
A+
Rated Heat Output (Prated)
11 kW
Seasonal Space Heating Energy Efficiency (ns)
117%
Annual Energy Consumption (Space Heating)
7803 kWh
Sound Power Level (Hydraulic Indoor Unit)
46 dB(A)
Sound Power Level (Outdoor Unit)
70 dB(A)
Model Name (Outdoor Unit)
WOYK140LCTA
Power Source (Outdoor Unit)
3 N 400 V 50 Hz
Noise Level (Sound Pressure) (Outdoor Unit)
55 dB(A)
Dimensions (Outdoor Unit) H×W×D
1290 × 900 × 330 mm
Weight (Net) (Outdoor Unit)
99 kg
Refrigerant Amount
2.50 kg
Additional Refrigerant Charge Amount
50 g/m
Connection Pipe Diameter (Liquid)
Φ9.52 mm
Connection Pipe Diameter (Gas)
Φ15.88 mm
Max Pipe Length (Chargeless)
15 m
Height Difference (Max)
15 m
Operation Range (Heating)
-25 ~ 35°C